Integrating Sound Level Meter with Real Time Octave Band Filters

  Intro Occupational Environmental Software Similar Meters  
 

Analyzer Software for the Pulsar 30 Real Time Sound Level Meter

software for octave band analyserThe Analyzer software is supplied free of charge with the Pulsar 30 sound level meter. It runs on a PC under MS Windows 95 or later and provides the following features:

  • Download Data from the sound level meter
  • Store measurements in folders for convenience
  • Enter Comments and Notes for each measurement
  • Display measurements individually or in a tabular format
  • Graphical display of Time History
  • Print reports
  • Exposure calculations for occupational noise applications
  • Enhanced Export functions (see below)

Now With Advanced Features:

  • Select Hearing Protection - calculates the "level at the ear" based on assumed protection given by hearing protector database
  • Calculate NR & NC figures from 1/1 Octave Band data
  • Graphical display of 1/1 Octave Band measurements

 

analyzer sound level meter softwareBroadband Measurements

Broadband Measurements are displayed in both a tabular and graphical format. The numerical values for the measurement are listed down the left side and include the time, date, duration and measurement range along with the Time and Frequency Weightings used for each parameter.

The Time History graph is shown on the right side. A zoom function is provided to allow more detail to be shown on the graph.

 

Frequency Measurements (Octave Band)

For Frequency Measurements made using 1/1 Octave Band Filters, the information is displayed as a bar graph, with the numerical data shown on the left. Comments and notes can also be entered for future reference.

Individual Frequency bands can be highlighted using the cursor. A and C Frequency Weightings can be applied by the software.

Analyzer also calculates and display NR and NC values and curves from 1/1 Octave Band Data.

 

Calculation of Exposure

The user can enter a different exposure time from the measurement duration, allowing the software to calculate the overall noise exposure in terms of the LEP,d according to the EU Physical Agents (Noise) Directive as well as many other occupational noise exposure regulations.

 

Hearing Protector Selection

Where 1/1 Octave Band Measurements are available, the Analyzer software can calculate the assumed protection from a range of Hearing Protector products from a database. The results can be filtered to remove, for example, protectors that do not reduce the noise level at the ear to below 85dB(A).

The database of hearing protectors can also be updated with new information as and when required.

 

Exporting Data

The Analyzer software can export data in a wide range of formats. The supported formats are:

  • Microsoft Excel
  • Microsoft Word
  • RTF
  • HTML
  • Text File
  • XML
  • DBF
  • CSV
  • DIFF
  • SYLK
  • LaTex
  • SQL
  • Windows Clipboard

In addition to the basic file format options, the data can be formatted in a number of ways depending upon the export options, including where appropriate fonts, colours, headers and footers, dates and file extensions. For full details please refer to the Help file provided with the Analyzer software.

 
   

Prices and Ordering

Order Code Description   Price Purchase
PULSAR30-2 Type 2 Sound Level Meter with Real Time Octave Band Filters in stock £1991.00 Purchase the PULSAR30-2
EMS230-2 Noise Measurement Kit with Pulsar 30-2, Calibrator and Software in stock £2298.00 Purchase the EMS230-2
PULSAR30 Type 1 Sound Level Meter with Real Time Octave Band Filters in stock £2440.00 Purchase the PULSAR30
EMS230 Noise Measurement Kit with Pulsar 30, Calibrator and Software in stock £2850.00 Purchase the EMS230
 
Options  
P105 Class 1 Acoustic Calibrator. 1kHz, 94dB. For 1/2 inch microphones in stock £345.00 Purchase the P105
P106 Class 2 Sound Level Calibrator. 1kHz, 94dB. For 1/2 inch microphones in stock £245.00 Purchase the P106
UA237 90mm Windshield for 1/2 inch Microphone Capsules in stock £16.00 Purchase the UA237
CRN-005 5m Microphone Extension Cable for Pulsar 30 and 33 lead time 1 week or less £120.00 Purchase the CRN-005
CRN-010 10m Microphone Extension Cable for Pulsar 30 and Pulsar 33 lead time 1 week or less £263.00 Purchase the CRN-010
CM270/1 Tripod Mount for Preamplifier lead time 1 week or less £32.00 Purchase the CM270/1
CT1 Lightweight Tripod in stock £53.00 Purchase the CT1
CT3 Tripod in stock £120.00 Purchase the CT3
PSU-P30 Power Supply for Pulsar 30 and 33 £73.00 Purchase the PSU-P30
 
Hire  
HP30WK One week hire of P30 Real-Time Analyser with Calibrator £241.00 Hire It

VAT not included - Delivery Charges

  noise at work Noise at Work environmental noise Environmental Noise general purpose noise meters General Purpose noise warning signs and controllers Signs and Controllers  

Home - Contact - News - Rental - Survey - Calibration - Resources - Search - Help
General Purpose - Signs - Noise at Work - Environmental - Accessories - Mobile Site

Telephone 0845 680 0312  
info@noisemeters.co.uk